Five steps. Shutting off the gas needs no mains power, no internet and no one at home — that is how it is designed.

Testing in progress Working prototype. This page describes how VenGuard is designed to work; independent testing and certification at BUET BRTC come before shipping.

  1. STEP 1 / 5

    Sensing

    The detector checks the kitchen air for LPG all the time. LPG is heavier than air, so the detector is mounted low.

  2. STEP 2 / 5

    The 7-second check

    So that a brief whiff while cooking does not cause a false alarm, VenGuard watches the level for 7 seconds to confirm it is a real leak.

    7 s limit
  3. STEP 3 / 5

    Closing the valve

    Once confirmed, the valve shuts off gas from the cylinder. It is designed to close in under 1 second.

  4. STEP 4 / 5

    Forced ventilation

    At the same time, the Active Ventilation Relay is designed to switch on the kitchen exhaust fan so the gas that has built up is pushed outside quickly. The fan needs mains power to run; without power, the valve still keeps the gas off.

  5. STEP 5 / 5

    Manual reset

    The valve stays closed until a person resets it. Open the windows too and leave switches alone; once the air is clear, reset it in about 10 seconds. This is deliberate, so gas never turns back on by itself.

What if…

What VenGuard does when things go wrong

VenGuard in special situations
SituationWhat VenGuard does
Power cut (load-shedding) The detector keeps running on its backup battery and the valve has its own batteries (2 × AA), so a leak still shuts off the gas and sounds the alarm. The exhaust fan needs mains power, so it cannot run during a power cut; the valve still keeps the gas off.
No Wi-Fi or internet Nothing changes. The detector, valve and relay talk to each other directly by radio, with no internet. Only phone alerts (Connected plan) wait for the internet to come back.
Cooking smells, steam, spices A brief whiff does nothing. VenGuard acts only when the gas stays above 20% LEL for 7 seconds in a row.
Nobody home, or everyone asleep Nobody has to do anything. The valve stays closed until someone comes and resets it by hand.
From the app With the Connected plan the app can shut the gas off from anywhere, but it can never turn it back on.

Manual reset

Why the gas comes back on only by hand

After a leak, someone has to see for themselves before gas flows again: that the smell has gone, the windows are open, and the cause (a loose hose or joint) has been fixed.

If gas could be turned on from a phone, nobody would be there to check, and gas could flow into a room that is still unsafe. So the valve stays closed until a person at the stove lifts the lever to reset it (about 10 seconds). The app can shut the gas off, never on.

Boundaries

What VenGuard does not do

The website never controls a valve

Protection happens entirely in the device.

It never turns gas back on by itself

A person always does the reset.

It does not depend on a subscription

Core Safety is never paywalled.

Reserve your VenGuard Home

BDT 500 deposit, fully refundable. The kit is BDT 3,500 and the deposit comes off the price. We call to confirm before delivery. Deliveries planned from March 2027, after testing and certification.

Pre-order